• ASTM A763-15

ASTM A763-15

  • standard by ASTM International, 03/01/2015
  • Standard Practices for Detecting Susceptibility to Intergranular Attack in Ferritic Stainless Steels
  • Category: ASTM

$72.00 $36.00

Full Description

1.1 These practices cover the following four tests:

1.1.1 Practice W-Oxalic acid etch test for detecting susceptibility to intergranular attack in stabilized ferritic stainless steels by classification of the etching structures (see Sections 3 - 10).

1.1.2 Practice X-Ferric sulfate-sulfuric acid test for detecting susceptibility to intergranular attack in ferritic stainless steels (Sections 11 - 16).

1.1.3 Practice Y-Copper-copper sulfate-50 % sulfuric acid test for detecting susceptibility to intergranular attack in ferritic stainless steels (Sections 17 - 22).

1.1.4 Practice Z-Copper-copper sulfate-16 % sulfuric acid test for detecting susceptibility to intergranular attack in ferritic stainless steels (Sections 23 - 29).

1.2 The following factors govern the application of these practices (1-6)2:

1.2.1 Practice W, oxalic acid test, is a rapid method of identifying, by simple electrolytic etching, those specimens of certain ferritic alloys that are not susceptible to intergranular corrosion associated with chromium carbide precipitation. Practice W is used as a screening test to avoid the necessity, for acceptable specimens, of more extensive testing required by Practices X, Y, and Z. See Table 1 for a listing of alloys for which Practice W is appropriate.

(A) Polished surface examined at 250 to 500× with a metallurgical microscope (see 3.1.6). All other microscopical examinations are of the corroded surface under 40× binocular examination (see Section 27).
(B) A = Applicable.
(C) Preferred criterion, these criteria are the most sensitive for the particular combination of alloy and test.
(D) Weight loss measurements can be used to detect severely sensitized material, but they are not very sensitive for alloys noted with this superscript and may not detect slight or moderate sensitization.
(E) NA = Not applicable.

1.2.2 Practices X, Y, and Z can be used to detect the susceptibility of certain ferritic alloys to intergr

Product Details

Published:
03/01/2015
Number of Pages:
11
File Size:
1 file , 660 KB
Redline File Size:
2 files , 1.7 MB
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

ASTM A763-15(2021)

ASTM A763-15

ASTM A763-14

ASTM A763-93(2004)

ASTM D2709-96(2001)e1

ASTM D2709-96(2001)e1

Standard Test Method for Water and Sediment in Middle Distillate Fuels by Centrifuge..

$26.00 $52.00

ASTM D6690-01

ASTM D6690-01

Standard Specification for Joint and Crack Sealants, Hot Applied, for Concrete and Asphalt Pavements..

$25.00 $50.00

ASTM C1052-96

ASTM C1052-96

Standard Practice for Bulk Sampling of Liquid Uranium Hexafluoride..

$27.00 $54.00

ASTM A820-01

ASTM A820-01

Standard Specification for Steel Fibers for Fiber-Reinforced Concrete..

$27.00 $54.00