• ASTM D3764-06e1

ASTM D3764-06e1

  • standard by ASTM International, 07/01/2006
  • Standard Practice for Validation of the Performance of Process Stream Analyzer Systems
  • Category: ASTM

$67.00 $34.00

Full Description

1.1 This practice describes procedures and methodologies based on the statistical principles of Practice D 6708 to validate whether the degree of agreement between the results produced by a total analyzer system (or its subsystem), versus the results produced by an independent test method that purports to measure the same property, meets user-specified requirements. This is a performance-based validation, to be conducted using a set of materials that are not used a priori in the development of any correlation between the two measurement systems under investigation. A result from the independent test method is herein referred to as a Primary Test Method Result (PTMR).

1.2 This practice assumes any correlation necessary to mitigate systemic biases between the analyzer system and PTM have been applied to the analyzer results.

1.3 This practice requires that both the primary method against which the analyzer is compared to, and the analyzer system under investigation, are in statistical control. Practices described in Practice D 6299 should be used to ensure this condition is met.

1.4 This practice applies if the process stream analyzer system and the primary test method are based on the same measurement principle(s), or, if the process stream analyzer system uses a direct and well-understood measurement principle that is similar to the measurement principle of the primary test method. This practice also applies if the process stream analyzer system uses a different measurement technology from the primary test method, provided that the calibration protocol for the direct output of the analyzer does not require use of the PTMRs (see Case 1 in Note 1).

1.5 This practice does not apply if the process stream analyzer system utilizes an indirect or mathematically modeled measurement principle such as chemometric or multivariate analysis techniques where PTMRs are required for the chemometric or multivariate model development. Users should refer to Practice D 6122 for detailed validation procedures for these types of analyzer systems (see Case 2 in ).

Note 0

For example, for the measurement of benzene in spark ignition fuels, comparison of a Mid-Infrared process analyzer system based on Test Method D 6277 to a Test Method D 3606 gas chromatography primary test method would be considered Case 1, and this practice would apply. For each sample, the Mid-Infrared spectrum is converted into a single analyzer result using methodology (Test Method D 6277) that is independent of the primary test method (Test Method D 3606). However, when the same analyzer uses a multivariate model to correlate the measured Mid-Infrared spectrum to Test Method D 3606 reference values using the methodology of Practice E 1655, it is considered Case 2 and Practice D 6122 applies. In this case 2 example, the direct output of the analyzer is the spectrum, and the conversion of this multivariate output to an analyzer result require use of Practice D 6122, hence it is not independent of the primary test method.

1.6 Performance Validation is conducted by calculating the precision and bias of the differences between results from the analyzer system (or subsystem) after the application of any necessary correlation, (such results are herein referred to as Predicted Primary Test Method Results (PPTMRs)), versus the PTMRs for the same sample set. Results used in the calculation are for samples that are not used in the development of the correlation. The calculated precision and bias are statistically compared to user-specified requirements for the analyzer system application.

1.6.1 For analyzers used in product release or product quality certification applications, the precision and bias requirement for the degree of agreement are typically based on the site or published precision of the Primary Test Method.

Note 2

In most applications of this type, the PTM is the specification-cited test method.

1.6.2 This practice does not describe procedures for establishing precision and bias requirements for analyzer system applications. Such requirements must be based on the criticality of the results to the intended business application and on contractual and regulatory requirements. The user must establish precision and bias requirements prior to initiating the validation procedures described herein.

1.7 Two procedures for validation are described: the line sample procedure and the validation reference material (VRM) injection procedure.

1.8 Only the analyzer system or subsystem downstream of the VRM injection point or the line sample extraction point is being validated by this practice.

1.9 The line sample procedure is limited to applications where material can be safely withdrawn from the sampling point of the analyzer unit without significantly altering the property of interest.

1.10 V

Product Details

Published:
07/01/2006
Number of Pages:
16
File Size:
1 file , 290 KB
Redline File Size:
2 files , 580 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

ASTM D3764-19

ASTM D3764-15e1

ASTM D3764-15

ASTM D3764-06e1

ASTM D3764-06

ASTM D3764-92(1998)

ASTM A974-97(2003)

ASTM A974-97(2003)

Standard Specification for Welded Wire Fabric Gabions and Gabion Mattresses (Metallic Coated or Poly..

$30.00 $60.00

ASTM A743/A743M-03

ASTM A743/A743M-03

Standard Specification for Castings, Iron-Chromium, Iron-Chromium-Nickel, Corrosion Resistant, for G..

$30.00 $60.00

ASTM D6864-03a

ASTM D6864-03a

Standard Specification for Color and Appearance Retention of Solid Colored Plastic Siding Products..

$26.00 $52.00

ASTM C800-03e1

ASTM C800-03e1

Standard Specification for Glass Fiber Blanket Insulation (Aircraft Type)..

$30.00 $60.00