1.1 This guide defines conventions for personal samplers of specific particle-size-dependent fractions of any given non-fibrous airborne aerosol. Such samplers are used for assessing health effects and in the setting of and testing for compliance with permissible exposure limits in the workplace and ambient environment. The conventions have been adopted by the International Standards Organization (ISO 7708), the Comité Européen de Normalisation (CEN EN 481), and the American Conference of Governmental Industrial Hygienists (ACGIH) (1).2 The conventions were developed (2) in part from health-effects studies reviewed (3) by the ACGIH and in part as a compromise between definitions proposed by the ACGIH (3) and by the British Medical Research Council (BMRC) (4). Conventions are given here for inhalable, thoracic, and respirable fractions.

1.2 This guide is complementary to Test Method D4532, which describes the performance of respirable dust cyclones and operational procedures for use. The procedures, specifically the optimal flow rate, are still valid although the estimated accuracy differs somewhat from use with previous aerosol fraction definitions. Details on these instruments have been published (5-11).

1.3 Limitations: 

1.3.1 The definitions given here were adopted by the agencies listed in 1.1 in part on the basis of expected health effects of the different size fractions, but in part allowing for available sampling equipment. The original adoption by CEN was, in fact, for the eventual setting of common standards by the EC countries while permitting the use of a variety of instrumentation. Deviations of the sampling conventions from health-related effects are as follows:

1.3.1.1 The inhalable fraction actually depends on the specific air speed and direction, on the breathing rate, and on whether breathing is by nose or mouth. The values given in the inhalable convention are for representative values of breathing rate and represent averages over all wind directions.

1.3.1.2 The respirable and thoracic fractions vary from individual to individual and with the breathing pattern. The conventions are approximations to the average case.

1.3.1.3 Each convention applies strictly to a fraction penetrating to a region, rather than depositing. Therefore, samples collected according to the conventions may only approximate correlations with biological effects. For example, the respirable convention overestimates the fraction of very small particles deposited in the alveolar region of the respiratory system because some of the particles are actually exhaled without being deposited (12). In many workplaces, these very small particles contribute insignificantly to the sampled mass. Furthermore, the large variability between individuals and the details of clearance may be as important as this type of effect.

1.3.1.4 The thoracic convention applies to mouth breathing, for which aerosol collection is greater than during nose breathing.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

Product Details
Published:
04/01/2019
Number of Pages:
4
File Size:
1 file , 120 KB
Redline File Size:
2 files , 250 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

ASTM D6062-19

ASTM F891-09

ASTM F891-09

Standard Specification for Coextruded Poly(Vinyl Chloride) (PVC) Plastic Pipe With a Cellular Core..

$29.00 $58.00

ASTM E170-09a

ASTM E170-09a

Standard Terminology Relating to Radiation Measurements and Dosimetry..

$30.00 $60.00

ASTM D7506/D7506M-09

ASTM D7506/D7506M-09

Standard Test Method for Pocket Reinforcement..

$25.00 $50.00

ASTM F1488-09e1

ASTM F1488-09e1

Standard Specification for Coextruded Composite Pipe..

$33.00 $65.00