• ASTM E336-19

ASTM E336-19

  • standard by ASTM International, 01/01/2019
  • Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
  • Category: ASTM

$67.00 $34.00

Full Description

1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission through the nominally separating building element (as normally measured in a laboratory) and any transmission along a number of indirect paths, referred to as flanking paths. Fig. 1 illustrates the direct paths (D) and some possible structural flanking paths (F). Additional non-structural flanking paths include transmission through common air ducts between rooms, or doors to the corridor from adjacent rooms. Sound isolation is also influenced by the size of the separating partition between spaces and absorption in the receiving space, and in the case of small spaces by modal behavior of the space and close proximity to surfaces.

FIG. 1 Direct (D) and Some Indirect or Flanking Paths (F and Dotted) in a Building

Direct (D) and Some Indirect or Flanking Paths (F and
 Dotted) in a BuildingDirect (D) and Some Indirect or Flanking Paths (F and
 Dotted) in a Building

1.2 The main part of this test method defines procedures and metrics to assess the sound isolation between two rooms or portions thereof in a building separated by a common partition or the apparent sound insulation of the separating partition, including both direct and flanking transmission paths in all cases. Appropriate measures and their single number ratings are the noise reduction (NR) and noise isolation class (NIC) which indicate the isolation with the receiving room furnished as it is during the test, the normalized noise reduction (NNR) and normalized noise isolation class (NNIC) which indicate the isolation expected if the receiving room was a normally furnished living or office space that is at least 25 m³ (especially useful when the test must be done with the receiving room unfurnished), and the apparent transmission loss (ATL) and apparent sound transmission class (ASTC) which indicate the apparent sound insulating properties of a separating partition including both the direct transmission and flanking transmission through the support structure. The measurement of ATL is limited to spaces of at least 25 m³ where modal effects create fewer problems. With the exception of the ATL and ASTC under specified conditions, these procedures in the main part of the test method are only applicable when both room volumes are less than 150 m³.

Note 1: The word “partition” in this test method includes all types of walls, floors, or any other boundaries separating two spaces including those that are permanent, operable, or movable.

1.3 The NR and NIC between two locations are always measureable and reportable though conditions present will influence how measurements are performed. With one exception (see 13.5.1), it is required that the NIC always be reported. Restrictions such as minimum room volume or dimensions or maximum room absorption are imposed for all other measures and ratings in this standard. Thus, conditions sometimes exist that will not allow NNR (NNIC) or ATL (ASTC) to be reported. Where a partition between rooms is composed of parts that are constructed differently, or contains an element such as a door, the ATL and ASTC of the individual elements or portions of the partition are not measurable without modifications to the rooms. To evaluate the field performance of a door less than 6 m² in area, use Test Method E2964. The various metrics are inherently different quantities, so that NIC cannot be used instead of NNIC or ASTC to evaluate compliance with a specification when the specification is written in terms of one of those metrics that cannot be reported with the conditions present.

1.4 Annex A1 provides methods to measure the sound isolation between portions of two rooms in a building separated by a common partition including both direct and flanking paths when at least one of the rooms has a volume of 150 m³ or more. The results are the noise reduction (NR) and noise isolation class (NIC).

Product Details

Published:
01/01/2019
Number of Pages:
15
File Size:
1 file , 250 KB
Redline File Size:
2 files , 550 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

ASTM E336-19a

ASTM E336-19

ASTM E336-17a

ASTM E336-16a

ASTM E336-16

ASTM E336-15

ASTM E336-14

ASTM E336-09

ASTM E336-08

ASTM E336-05

ASTM E336-97e1

ASTM E336-97

ASTM B733-04

ASTM B733-04

Standard Specification for Autocatalytic (Electroless) Nickel-Phosphorus Coatings on Metal..

$34.00 $67.00

ASTM F432-04

ASTM F432-04

Standard Specification for Roof and Rock Bolts and Accessories..

$33.00 $65.00

ASTM F436M-04

ASTM F436M-04

Standard Specification for Hardened Steel Washers [Metric]..

$29.00 $58.00

ASTM F835-04

ASTM F835-04

Standard Specification for Alloy Steel Socket Button and Flat Countersunk Head Cap Screws..

$29.00 $58.00