• ASTM F2148-18

ASTM F2148-18

  • standard by ASTM International, 12/01/2018
  • Standard Practice for Evaluation of Delayed Contact Hypersensitivity Using the Murine Local Lymph Node Assay (LLNA)
  • Category: ASTM

$48.00 $24.00

Full Description

1.1 This practice provides a methodology to use a combination of in vivio and in situ procedures for the evaluation of delayed contact hypersensitivity reactions.

1.2 This practice is intended to provide an alternative to the use of guinea pigs for evaluation of the ability of a device material to stimulate delayed contact hypersensitivity reactions. This alternative is particularly applicable for materials used in devices that contact only intact skin. However, the guinea pig maximization test is still the recommended method when assessing the delayed hypersensitivity response to metals or when testing substances that do not penetrate the skin but are used in devices that contact deep tissues or breached surfaces. This practice may be used for testing metals, with the exception of nickel-containing metals, unless the unique physicochemical properties of the materials may interfere with the ability of LLNA to detect sensitizing substances.

1.3 This practice consists of a protocol for assessing an increase in lymphocyte proliferation in the lymph nodes draining the site of test article administration on the ears of mice.

1.4 The LLNA has been validated only for low-molecular-weight chemicals that can penetrate the skin. The absorbed chemical or metabolite must bind to macromolecules, such as proteins, to form immunogenic conjugates.

1.5 This practice is one of several developed for the assessment of the biocompatibility of materials. Practice F748 may provide guidance for the selection of appropriate methods for testing materials for a specific application.

1.6 Identification of a supplier of materials or reagents is for the convenience of the user and does not imply a single source. Appropriate materials and reagents may be obtained from many commercial supply houses.

1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Product Details

Published:
12/01/2018
Number of Pages:
5
File Size:
1 file , 83 KB
Redline File Size:
2 files , 160 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

ASTM F2148-18

ASTM F2148-13

ASTM F2148-07(2012)

ASTM F2148-07e1

ASTM F2148-06a

ASTM F2148-06

ASTM D710-97(2009)e1

ASTM D710-97(2009)e1

Standard Specification for Vulcanized Fibre Sheets, Rods, and Tubes Used for Electrical Insulation..

$30.00 $60.00

ASTM C1377-97(2009)

ASTM C1377-97(2009)

Standard Test Method for Calibration of Surface/Stress Measuring Devices (Withdrawn 2014)..

$30.00 $60.00

ASTM C676-04(2009)

ASTM C676-04(2009)

Standard Test Method for Detergent Resistance of Ceramic Decorations on Glass Tableware..

$26.00 $52.00

ASTM A565/A565M-05a(2009)

ASTM A565/A565M-05a(2009)

Standard Specification for Martensitic Stainless Steel Bars for High-Temperature Service..

$26.00 $52.00