• ASTM F882-84(1996)

ASTM F882-84(1996)

  • standard by ASTM International, 01/01/1996
  • Standard Performance and Safety Specification for Cryosurgical Medical Instruments
  • Category: ASTM

$58.00 $29.00

Full Description

1.1 This specification establishes standards a manufacturer shall meet in the designing, manufacturing, testing, labeling, and documenting of cryosurgical medical instruments, but it is not to be construed as production methods, quality control techniques, or manufacturer's lot release criteria, or clinical recommendations.

1.2 This specification represents the best currently available test procedures at this time and is a minimum safety and performance standard.

1.3 This specification covers only those cryosurgical devices intended for use on humans or animals for therapeutic purposes. This specification assumes the user is well-trained in the procedures of cryosurgery and has the ability to determine if an abnormality is treatable by cryosurgery, particularly by the type of equipment to be used.

1.4 Cryosurgical medical instruments produce low temperatures either inside a cryoprobe or directly on the target tissue by the principle of Latent Heat of Vaporization or the Joule-Thompson Effect, or both. The cryogen may be transported from the source as a liquid or a gas. These systems may be closed or open depending on the application and cryogen. In the open cryotip system, the cryogen is applied directly to the target tissue, while in the closed cryotip system, the cryogen is applied indirectly and is exhausted away from the target area.

1.5 Cryosurgical medical instruments are used to produce cryonecrosis, inflammatory response, or cryoadhesion.

1.6 Monitoring the progress of treatment during application is sometimes very important. Such monitoring is done by accessories that indicate the temperature of the cryotip or the target area being frozen. The temperature of the tissue may be measured directly (for example, by a thermocouple). These accessories are also covered by this specification.

1.7 The following precautionary caveat pertains only to the Test Method portion, Sections 8 through 13, of this specification: This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Product Details

Published:
01/01/1996
Number of Pages:
7
File Size:
1 file , 67 KB
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

ASTM F882-84(1996)

ASTM F882-84(2002)

ASTM D6065-00

ASTM D6065-00

Standard Practice for Handling, Transporation, and Storage of HFC-227ea 1,1,1,2,3,3,3-Heptafluoropro..

$25.00 $50.00

ASTM F504-00

ASTM F504-00

Standard Test Method for Measuring the Quasi-Static Release Moments of Alpine Ski Bindings..

$29.00 $58.00

ASTM E587-00

ASTM E587-00

Standard Practice for Ultrasonic Angle-Beam Examination by the Contact Method..

$29.00 $58.00

ASTM E2068-00

ASTM E2068-00

Standard Test Method for Determination of Operating Force of Sliding Windows and Doors..

$29.00 $58.00