CSA C22.2 NO. 178.1:14 (R2019)

  • standard by CSA Group, 12/01/2014
  • Transfer Switch Equipment, Includes Update No. 1 (2015) and Update No. 2 (2018)
  • Category: CSA GROUP

$528.00 $264.00

Full Description

Scope:

1.1
This standard applies to the following types of transfer switches that have a maximum rating of 1000 volts for use in non-hazardous locations, in accordance with Annex A1, Item 1:
a) Automatic transfer switches;
b) Manual or non-automatic transfer switches;
c) Closed transition transfer switches;
d) Hybrid transfer switches;
e) Transfer switches for fire pumps;
f) Bypass/isolating switches;
g) Softload transfer switches;
h) Transfer switches intended for use as service equipment; and
i) In Mexico and the United States, branch circuit emergency lighting transfer switches (BCELTS). In Canada, requirements for BCELTS do not apply.

1.2
This standard specifically does not apply to:
a) Double-throw switches for use in optional standby systems;
b) Switches used in equipment manufactured in accordance with Annex A1, Item 9;
c) In Canada, manually operated generator transfer panels in accordance with Annex A1, Item 12. In Mexico, this requirement does not apply.
d) Transfer switches rated over 1000 V; and
e) Solid-state (static) transfer equipment.

1.3
These requirements apply to transfer switches and their associated control devices including voltage sensing relays, frequency sensing relays, time-delay relays, and the like.

1.4
These requirements apply to completely enclosed transfer switches and to open types intended for mounting in other equipment such as switchboards.

1.5
These requirements apply to bypass/isolation switches used to manually select an available power source to feed load circuits and to provide for total isolation of an automatic transfer switch. These switches may be completely enclosed, enclosed with the transfer switch, or of the open type intended for mounting in other equipment. Refer to Annex D.

1.6
In Canada, automatic transfer switches built to the optional standby requirements of this standard are not permitted. In Mexico and the United States, this requirement does not apply.

1.7
These requirements cover enclosed inlets intended to facilitate connection of portable generators to transfer equipment.

Product Details

Edition:
3rd
Published:
12/01/2014
ISBN(s):
9781771399371
Number of Pages:
265
File Size:
1 file , 2.1 MB
Product Code(s):
2423047, 2423047
Note:
This product is unavailable in Russia, Ukraine, Belarus

Document History

CSA C22.2 NO. 178.1:22

CSA C22.2 NO. 178.1:14 (R2019)

CSA C22.2 NO. 178.1-12

CSA C22.2 NO. 178.1-07

CSA C22.2 NO. 178-1978 (R2006)

CSA 2.16-M81 (R1996)

CSA 2.16-M81 (R1996)

Gas-Fired Infra-Red Heaters..

$55.00 $110.00

CSA C22.2 NO. 109-M1981 (R2013)

CSA C22.2 NO. 109-M1981 (R2013)

Commercial Cooking Appliances..

$43.00 $85.00

CSA C22.2 NO. 137-M1981 (R2014)

CSA C22.2 NO. 137-M1981 (R2014)

Electric Luminaires for Use in Hazardous Locations..

$102.00 $204.00

CSA C22.2 NO. 46-M81

CSA C22.2 NO. 46-M81

Electric Air-Heaters - WITHDRAWN - S/S by C22.2 No. 46-M88..

$140.00 $279.00